Turnkey HVAC Equipment
End-to-end supply, installation, commissioning and handover for AHUs, FCUs, FFUs, air washers, curtains and clean rooms.
About the Turnkey HVAC Equipment
Turnkey delivery of the air-side equipment that makes an HVAC system work — from the central Air Handling Unit (AHU) that filters, conditions and pushes air through the building, down to the Fan Coil Units (FCUs) at the room level and the Fan Filter Units (FFUs) that maintain cleanroom-grade air. We handle selection, supply, installation, water and electrical interconnection, testing-adjusting-balancing (TAB) and commissioning, then hand the system over with a complete documentation set.
Engineering Advantages
Single point of accountability — one contract from selection to handover
Equipment selection optimised across the full system, not piecemeal
In-house TAB and commissioning team — no separate sub-contract
Documented handover: O&M manuals, balance reports, as-built drawings, training
Key Features
- Air Handling Units (AHU)
- Air Washer Systems
- Fan Coil Units (FCU)
- Fan Filter Units (FFU)
- Air Curtains
- Air Distribution Terminals (grilles, diffusers, etc.)
- Complete Clean Rooms (panels, HVAC, ducting, electrical)
Construction & Materials
- AHU: double-skin panel construction with PUF / mineral wool insulation; EUROVENT-class casing options
- FCU: 2-pipe / 4-pipe configuration; horizontal or vertical with chassis or concealed body
- FFU: HEPA H13 / H14 filtration with terminal fan-filter modules for cleanrooms
- Air washers: cellulose pad media or spray-type with stainless-steel drift eliminator
- Air curtains: ambient or heated; sized to door width for full cut-off
How to Choose the Right Variant
- 1AHU sizing: airflow at design external static pressure (ESP); confirm filter / coil class against project spec
- 2FCU sizing: room sensible + latent load; size for design entering air condition
- 3FFU coverage: ISO 14644-1 class drives the percentage of ceiling covered
- 4Air curtain: choose nozzle width = door width; jet velocity 6–10 m/s at floor level
Installation Notes
- Provide a structural plinth for every AHU; never sit one on a slab without isolation
- Allow service-side clearance ≥ AHU width for filter changes and coil pull
- Hydraulic balance the chilled-water loop before commissioning the air side
- Run a full TAB after install — every project ships with a balance report
Maintenance Schedule
- Filters: monitor pressure drop; replace at design final pressure
- Coils: clean annually with low-pressure water + mild detergent
- Belts: inspect quarterly; replace yearly
- Drain pans: clean and treat for biofilm at every coil-cleaning visit
Industries Served
Standards & Compliance
- AHU casing per EUROVENT casing-class practice
- TAB per AABC / NEBB methodology
- Cleanroom delivery to ISO 14644-1 classification
- Filtration ratings per ISO 16890 / EN 1822 (HEPA)
Frequently Asked Questions
What does turnkey actually include?
Survey, selection, equipment supply, installation, ducting, water/electrical connections, controls integration, TAB, commissioning, O&M training, and a one- or two-year defects warranty.
Can we just buy the AHU and install it ourselves?
Yes — equipment-only supply is available. Turnkey is the option for owners who want a single point of accountability and a documented handover.
Related Turnkey HVAC — End-to-End Solutions
Need help selecting the right fan?
Our engineers will help you size the turnkey hvac equipment to your exact application — capacity, static pressure, and installation constraints.